ALSA: ICE1712/24 - Change the Multi Track Peak control (level meters) from MIXER...
authorPavel Hofman <pavel.hofman@ivitera.com>
Tue, 6 Oct 2009 14:04:11 +0000 (16:04 +0200)
committerTakashi Iwai <tiwai@suse.de>
Thu, 8 Oct 2009 09:47:56 +0000 (11:47 +0200)
commit2bdf66331c3ff8d564efe7a054f1099133d520cd
tree8864418fb40ce259c4be7d603cab16cece6acfb3
parent2fb930b53f513cbc4c102d415d2923a8a7091337
ALSA: ICE1712/24 - Change the Multi Track Peak control (level meters) from MIXER to PCM type

* PLEASE NOTE - this change requires the corresponding update of
  envy24control for ice1712 - kind of an ABI change.
* The "Multi Track Peak" control is read-only level meters indicator.
* The control is VERY confusing to most users since it is currently displayed
  in regular mixers. E.g. alsamixer ignores its read-only status
  and allows changing the levels with keys which makes no sense.

Signed-off-by: Pavel Hofman <pavel.hofman@ivitera.com>
Acked-by: Jaroslav Kysela <perex@perex.cz>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
sound/pci/ice1712/ice1712.c
sound/pci/ice1712/ice1724.c