[S390] dasd: support DIAG access for read-only devices
authorStefan Weinhuber <wein@de.ibm.com>
Mon, 7 Dec 2009 11:51:48 +0000 (12:51 +0100)
committerMartin Schwidefsky <sky@mschwide.boeblingen.de.ibm.com>
Mon, 7 Dec 2009 11:51:34 +0000 (12:51 +0100)
commit22825ab7693fd29769518a0d25ba43c01a50092a
treeb4cc2d22baafb8851efac2fed87fda4982dd8209
parent6c1e3e79430615d0472dbf9f8fed89c571e66423
[S390] dasd: support DIAG access for read-only devices

When a DASD device is used with the DIAG discipline, the DIAG
initialization will indicate success or error with a respective
return code. So far we have interpreted a return code of 4 as error,
but it actually means that the initialization was successful, but
the device is read-only. To allow read-only devices to be used with
DIAG we need to accept a return code of 4 as success.

Re-initialization of the DIAG access is also part of the DIAG error
recovery. If we find that the access mode of a device has been
changed from writable to read-only while the device was in use,
we print an error message.

Signed-off-by: Stefan Weinhuber <wein@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
drivers/s390/block/dasd_diag.c