[POWERPC] spufs: DMA Restart after SIGSEGV
authorAndre Detsch <adetsch@br.ibm.com>
Thu, 20 Dec 2007 07:39:59 +0000 (16:39 +0900)
committerPaul Mackerras <paulus@samba.org>
Fri, 21 Dec 2007 08:46:21 +0000 (19:46 +1100)
commit18789fb1c3311dd8c25acb6eb5ccab05771843f2
treef3b39752fe624f37de34966908be8829840ce850
parent90608a2928a86b9464a8698275a1138e82e3a010
[POWERPC] spufs: DMA Restart after SIGSEGV

This fixes the behavior of spufs when a spu tries a DMA operation
based on a wrong / unavailable address.

Instead of just generating a SIGBUS signal, spufs now
generates a SIGSEGV signal and restarts the problematic DMA operation
after the execution of the application's signal handler.  This allows
applications to employ user-level paging systems.

Although the restart_dma function is called before the application's
signal handler, the operation is not actually performed at this time,
since the spu context is already stopped.  The operation only takes
place when spu_run is restarted (which happens automatically).