tty: serial: OMAP: use a 1-byte RX FIFO threshold in PIO mode
authorPaul Walmsley <paul@pwsan.com>
Thu, 26 Jan 2012 02:50:36 +0000 (19:50 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 9 Feb 2012 18:48:32 +0000 (10:48 -0800)
commit0ba5f66836c9253c67c469fb4016f94ea30ff2ce
treedf0c699312cd9de2d97164034971f0e3988554bd
parentc8a64268d187b2ace478d2147ce5c79658aca2d2
tty: serial: OMAP: use a 1-byte RX FIFO threshold in PIO mode

In the (default) PIO mode, use a one-byte RX FIFO threshold.  The OMAP
UART IP blocks do not appear to be capable of waking the system under
an RX timeout condition.  Since the previous RX FIFO threshold was 16
bytes, this meant that omap-serial.c did not become aware of any
received data until all those bytes arrived or until another UART
interrupt occurred.  This made the serial console and presumably other
serial applications (GPS, serial Bluetooth) unusable or extremely
slow.  A 1-byte RX FIFO threshold also allows the MPU to enter a
low-power consumption state while waiting for the FIFO to fill.

This can be verified using the serial console by comparing the
behavior when "0123456789abcde" is pasted in from another window, with
the behavior when "0123456789abcdef" is pasted in.  Since the former
string is less than sixteen bytes long, the string is not echoed for
some time, while the latter string is echoed immediately.

DMA operation is unaffected by this patch.

Thanks to Russell King - ARM Linux <linux@arm.linux.org.uk> for some
additional information on the standard behavior of the RX timeout
event, which was used to improve this commit description.

Signed-off-by: Paul Walmsley <paul@pwsan.com>
Cc: Tomi Valkeinen <tomi.valkeinen@ti.com>
Cc: Govindraj Raja <govindraj.r@ti.com>
Cc: Alan Cox <alan@linux.intel.com>
Cc: Russell King <linux@arm.linux.org.uk>
Reviewed-by: Kevin Hilman <khilman@ti.com>
Tested-by: Kevin Hilman <khilman@ti.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/tty/serial/omap-serial.c