net: phy: Do not perform software reset for Generic PHY
The Generic PHY driver is a catch-all PHY driver and it should preserve
whatever prior initialization has been done by boot loader or firmware
agents. For specific PHY device configuration it is expected that a
specialized PHY driver would take over that role.
Resetting the generic PHY was a bad idea that has lead to several
complaints and downstream workarounds e.g: in OpenWrt/LEDE so restore
the behavior prior to
87aa9f9c61ad ("net: phy: consolidate PHY
reset in phy_init_hw()").
Reported-by: Felix Fietkau <nbd@nbd.name>
Fixes:
87aa9f9c61ad ("net: phy: consolidate PHY reset in phy_init_hw()")
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>