mceusb: sporadic RX truncation corruption fix
[ Upstream commit
8e175b22e8640bf3a58e071af54190b909e4a944 ]
Intermittent RX truncation and loss of IR received data. This resulted
in receive stream synchronization errors where driver attempted to
incorrectly parse IR data (eg 0x90 below) as command response.
[ 3969.139898] mceusb 1-1.2:1.0: processed IR data
[ 3969.151315] mceusb 1-1.2:1.0: rx data: 00 90 (length=2)
[ 3969.151321] mceusb 1-1.2:1.0: Unknown command 0x00 0x90
[ 3969.151336] mceusb 1-1.2:1.0: rx data: 98 0a 8d 0a 8e 0a 8e 0a 8e 0a 8e 0a 9a 0a 8e 0a 0b 3a 8e 00 80 41 59 00 00 (length=25)
[ 3969.151341] mceusb 1-1.2:1.0: Raw IR data, 24 pulse/space samples
[ 3969.151348] mceusb 1-1.2:1.0: Storing space with duration 500000
Bug trigger appears to be normal, but heavy, IR receiver use.
Signed-off-by: A Sun <as1033x@comcast.net>
Signed-off-by: Sean Young <sean@mess.org>
Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>