our_mcs = (le16_to_cpu(vht_cap.vht_mcs.rx_mcs_map) &
mask) >> shift;
+ if (our_mcs == IEEE80211_VHT_MCS_NOT_SUPPORTED)
+ continue;
+
switch (ap_mcs) {
default:
if (our_mcs <= ap_mcs)
{
struct ieee80211_if_managed *ifmgd = &sdata->u.mgd;
+ /*
+ * Stop timers before deleting work items, as timers
+ * could race and re-add the work-items. They will be
+ * re-established on connection.
+ */
+ del_timer_sync(&ifmgd->conn_mon_timer);
+ del_timer_sync(&ifmgd->bcn_mon_timer);
+
/*
* we need to use atomic bitops for the running bits
* only because both timers might fire at the same
if (del_timer_sync(&ifmgd->timer))
set_bit(TMR_RUNNING_TIMER, &ifmgd->timers_running);
- cancel_work_sync(&ifmgd->chswitch_work);
if (del_timer_sync(&ifmgd->chswitch_timer))
set_bit(TMR_RUNNING_CHANSW, &ifmgd->timers_running);
-
- /* these will just be re-established on connection */
- del_timer_sync(&ifmgd->conn_mon_timer);
- del_timer_sync(&ifmgd->bcn_mon_timer);
+ cancel_work_sync(&ifmgd->chswitch_work);
}
void ieee80211_sta_restart(struct ieee80211_sub_if_data *sdata)
{
struct ieee80211_if_managed *ifmgd = &sdata->u.mgd;
+ /*
+ * Make sure some work items will not run after this,
+ * they will not do anything but might not have been
+ * cancelled when disconnecting.
+ */
+ cancel_work_sync(&ifmgd->monitor_work);
+ cancel_work_sync(&ifmgd->beacon_connection_loss_work);
+ cancel_work_sync(&ifmgd->request_smps_work);
+ cancel_work_sync(&ifmgd->csa_connection_drop_work);
+ cancel_work_sync(&ifmgd->chswitch_work);
+
mutex_lock(&ifmgd->mtx);
if (ifmgd->assoc_data)
ieee80211_destroy_assoc_data(sdata, false);