1 Generic Thermal Sysfs driver How To
2 ===================================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c) 2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone
14 devices (sensors) and thermal cooling devices (fan, processor...) to register
15 with the thermal management solution and to be a part of it.
16
17 This how-to focuses on enabling new thermal zone and cooling devices to
18 participate in thermal management.
19 This solution is platform independent and any type of thermal zone devices
20 and cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes
23 as well as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on
25 inputs from thermal zone attributes (the current temperature and trip point
26 temperature) and throttle appropriate devices.
27
28 [0-*] denotes any positive number starting from 0
29 [1-*] denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35 int trips, int mask, void *devdata,
36 struct thermal_zone_device_ops *ops,
37 const struct thermal_zone_params *tzp,
38 int passive_delay, int polling_delay))
39
40 This interface function adds a new thermal zone device (sensor) to
41 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42 thermal cooling devices registered at the same time.
43
44 type: the thermal zone type.
45 trips: the total number of trip points this thermal zone supports.
46 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47 devdata: device private data
48 ops: thermal zone device call-backs.
49 .bind: bind the thermal zone device with a thermal cooling device.
50 .unbind: unbind the thermal zone device with a thermal cooling device.
51 .get_temp: get the current temperature of the thermal zone.
52 .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53 - "enabled" means the kernel thermal management is enabled.
54 - "disabled" will prevent kernel thermal driver action upon trip points
55 so that user applications can take charge of thermal management.
56 .set_mode: set the mode (enabled/disabled) of the thermal zone.
57 .get_trip_type: get the type of certain trip point.
58 .get_trip_temp: get the temperature above which the certain trip point
59 will be fired.
60 .set_emul_temp: set the emulation temperature which helps in debugging
61 different threshold temperature points.
62 tzp: thermal zone platform parameters.
63 passive_delay: number of milliseconds to wait between polls when
64 performing passive cooling.
65 polling_delay: number of milliseconds to wait between polls when checking
66 whether trip points have been crossed (0 for interrupt driven systems).
67
68
69 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
71 This interface function removes the thermal zone device.
72 It deletes the corresponding entry form /sys/class/thermal folder and
73 unbind all the thermal cooling devices it uses.
74
75 1.2 thermal cooling device interface
76 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
77 void *devdata, struct thermal_cooling_device_ops *)
78
79 This interface function adds a new thermal cooling device (fan/processor/...)
80 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81 to all the thermal zone devices register at the same time.
82 name: the cooling device name.
83 devdata: device private data.
84 ops: thermal cooling devices call-backs.
85 .get_max_state: get the Maximum throttle state of the cooling device.
86 .get_cur_state: get the Current throttle state of the cooling device.
87 .set_cur_state: set the Current throttle state of the cooling device.
88
89 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
91 This interface function remove the thermal cooling device.
92 It deletes the corresponding entry form /sys/class/thermal folder and
93 unbind itself from all the thermal zone devices using it.
94
95 1.3 interface for binding a thermal zone device with a thermal cooling device
96 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
97 int trip, struct thermal_cooling_device *cdev,
98 unsigned long upper, unsigned long lower);
99
100 This interface function bind a thermal cooling device to the certain trip
101 point of a thermal zone device.
102 This function is usually called in the thermal zone device .bind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
107 upper:the Maximum cooling state for this trip point.
108 THERMAL_NO_LIMIT means no upper limit,
109 and the cooling device can be in max_state.
110 lower:the Minimum cooling state can be used for this trip point.
111 THERMAL_NO_LIMIT means no lower limit,
112 and the cooling device can be in cooling state 0.
113
114 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
115 int trip, struct thermal_cooling_device *cdev);
116
117 This interface function unbind a thermal cooling device from the certain
118 trip point of a thermal zone device. This function is usually called in
119 the thermal zone device .unbind callback.
120 tz: the thermal zone device
121 cdev: thermal cooling device
122 trip: indicates which trip point the cooling devices is associated with
123 in this thermal zone.
124
125 1.4 Thermal Zone Parameters
126 1.4.1 struct thermal_bind_params
127 This structure defines the following parameters that are used to bind
128 a zone with a cooling device for a particular trip point.
129 .cdev: The cooling device pointer
130 .weight: The 'influence' of a particular cooling device on this zone.
131 This is on a percentage scale. The sum of all these weights
132 (for a particular zone) cannot exceed 100.
133 .trip_mask:This is a bit mask that gives the binding relation between
134 this thermal zone and cdev, for a particular trip point.
135 If nth bit is set, then the cdev and thermal zone are bound
136 for trip point n.
137 .match: This call back returns success(0) if the 'tz and cdev' need to
138 be bound, as per platform data.
139 1.4.2 struct thermal_zone_params
140 This structure defines the platform level parameters for a thermal zone.
141 This data, for each thermal zone should come from the platform layer.
142 This is an optional feature where some platforms can choose not to
143 provide this data.
144 .governor_name: Name of the thermal governor used for this zone
145 .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
146 is required. when no_hwmon == false, a hwmon sysfs interface
147 will be created. when no_hwmon == true, nothing will be done.
148 In case the thermal_zone_params is NULL, the hwmon interface
149 will be created (for backward compatibility).
150 .num_tbps: Number of thermal_bind_params entries for this zone
151 .tbp: thermal_bind_params entries
152
153 2. sysfs attributes structure
154
155 RO read only value
156 RW read/write value
157
158 Thermal sysfs attributes will be represented under /sys/class/thermal.
159 Hwmon sysfs I/F extension is also available under /sys/class/hwmon
160 if hwmon is compiled in or built as a module.
161
162 Thermal zone device sys I/F, created once it's registered:
163 /sys/class/thermal/thermal_zone[0-*]:
164 |---type: Type of the thermal zone
165 |---temp: Current temperature
166 |---mode: Working mode of the thermal zone
167 |---policy: Thermal governor used for this zone
168 |---trip_point_[0-*]_temp: Trip point temperature
169 |---trip_point_[0-*]_type: Trip point type
170 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
171 |---emul_temp: Emulated temperature set node
172
173 Thermal cooling device sys I/F, created once it's registered:
174 /sys/class/thermal/cooling_device[0-*]:
175 |---type: Type of the cooling device(processor/fan/...)
176 |---max_state: Maximum cooling state of the cooling device
177 |---cur_state: Current cooling state of the cooling device
178
179
180 Then next two dynamic attributes are created/removed in pairs. They represent
181 the relationship between a thermal zone and its associated cooling device.
182 They are created/removed for each successful execution of
183 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
184
185 /sys/class/thermal/thermal_zone[0-*]:
186 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
187 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
188
189 Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
190 the generic thermal driver also creates a hwmon sysfs I/F for each _type_
191 of thermal zone device. E.g. the generic thermal driver registers one hwmon
192 class device and build the associated hwmon sysfs I/F for all the registered
193 ACPI thermal zones.
194
195 /sys/class/hwmon/hwmon[0-*]:
196 |---name: The type of the thermal zone devices
197 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
198 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
199
200 Please read Documentation/hwmon/sysfs-interface for additional information.
201
202 ***************************
203 * Thermal zone attributes *
204 ***************************
205
206 type
207 Strings which represent the thermal zone type.
208 This is given by thermal zone driver as part of registration.
209 E.g: "acpitz" indicates it's an ACPI thermal device.
210 In order to keep it consistent with hwmon sys attribute; this should
211 be a short, lowercase string, not containing spaces nor dashes.
212 RO, Required
213
214 temp
215 Current temperature as reported by thermal zone (sensor).
216 Unit: millidegree Celsius
217 RO, Required
218
219 mode
220 One of the predefined values in [enabled, disabled].
221 This file gives information about the algorithm that is currently
222 managing the thermal zone. It can be either default kernel based
223 algorithm or user space application.
224 enabled = enable Kernel Thermal management.
225 disabled = Preventing kernel thermal zone driver actions upon
226 trip points so that user application can take full
227 charge of the thermal management.
228 RW, Optional
229
230 policy
231 One of the various thermal governors used for a particular zone.
232 RW, Required
233
234 trip_point_[0-*]_temp
235 The temperature above which trip point will be fired.
236 Unit: millidegree Celsius
237 RO, Optional
238
239 trip_point_[0-*]_type
240 Strings which indicate the type of the trip point.
241 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
242 thermal zone.
243 RO, Optional
244
245 trip_point_[0-*]_hyst
246 The hysteresis value for a trip point, represented as an integer
247 Unit: Celsius
248 RW, Optional
249
250 cdev[0-*]
251 Sysfs link to the thermal cooling device node where the sys I/F
252 for cooling device throttling control represents.
253 RO, Optional
254
255 cdev[0-*]_trip_point
256 The trip point with which cdev[0-*] is associated in this thermal
257 zone; -1 means the cooling device is not associated with any trip
258 point.
259 RO, Optional
260
261 passive
262 Attribute is only present for zones in which the passive cooling
263 policy is not supported by native thermal driver. Default is zero
264 and can be set to a temperature (in millidegrees) to enable a
265 passive trip point for the zone. Activation is done by polling with
266 an interval of 1 second.
267 Unit: millidegrees Celsius
268 Valid values: 0 (disabled) or greater than 1000
269 RW, Optional
270
271 emul_temp
272 Interface to set the emulated temperature method in thermal zone
273 (sensor). After setting this temperature, the thermal zone may pass
274 this temperature to platform emulation function if registered or
275 cache it locally. This is useful in debugging different temperature
276 threshold and its associated cooling action. This is write only node
277 and writing 0 on this node should disable emulation.
278 Unit: millidegree Celsius
279 WO, Optional
280
281 WARNING: Be careful while enabling this option on production systems,
282 because userland can easily disable the thermal policy by simply
283 flooding this sysfs node with low temperature values.
284
285 *****************************
286 * Cooling device attributes *
287 *****************************
288
289 type
290 String which represents the type of device, e.g:
291 - for generic ACPI: should be "Fan", "Processor" or "LCD"
292 - for memory controller device on intel_menlow platform:
293 should be "Memory controller".
294 RO, Required
295
296 max_state
297 The maximum permissible cooling state of this cooling device.
298 RO, Required
299
300 cur_state
301 The current cooling state of this cooling device.
302 The value can any integer numbers between 0 and max_state:
303 - cur_state == 0 means no cooling
304 - cur_state == max_state means the maximum cooling.
305 RW, Required
306
307 3. A simple implementation
308
309 ACPI thermal zone may support multiple trip points like critical, hot,
310 passive, active. If an ACPI thermal zone supports critical, passive,
311 active[0] and active[1] at the same time, it may register itself as a
312 thermal_zone_device (thermal_zone1) with 4 trip points in all.
313 It has one processor and one fan, which are both registered as
314 thermal_cooling_device.
315
316 If the processor is listed in _PSL method, and the fan is listed in _AL0
317 method, the sys I/F structure will be built like this:
318
319 /sys/class/thermal:
320
321 |thermal_zone1:
322 |---type: acpitz
323 |---temp: 37000
324 |---mode: enabled
325 |---policy: step_wise
326 |---trip_point_0_temp: 100000
327 |---trip_point_0_type: critical
328 |---trip_point_1_temp: 80000
329 |---trip_point_1_type: passive
330 |---trip_point_2_temp: 70000
331 |---trip_point_2_type: active0
332 |---trip_point_3_temp: 60000
333 |---trip_point_3_type: active1
334 |---cdev0: --->/sys/class/thermal/cooling_device0
335 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
336 |---cdev1: --->/sys/class/thermal/cooling_device3
337 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
338
339 |cooling_device0:
340 |---type: Processor
341 |---max_state: 8
342 |---cur_state: 0
343
344 |cooling_device3:
345 |---type: Fan
346 |---max_state: 2
347 |---cur_state: 0
348
349 /sys/class/hwmon:
350
351 |hwmon0:
352 |---name: acpitz
353 |---temp1_input: 37000
354 |---temp1_crit: 100000
355
356 4. Event Notification
357
358 The framework includes a simple notification mechanism, in the form of a
359 netlink event. Netlink socket initialization is done during the _init_
360 of the framework. Drivers which intend to use the notification mechanism
361 just need to call thermal_generate_netlink_event() with two arguments viz
362 (originator, event). The originator is a pointer to struct thermal_zone_device
363 from where the event has been originated. An integer which represents the
364 thermal zone device will be used in the message to identify the zone. The
365 event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
366 THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
367 crosses any of the configured thresholds.
368
369 5. Export Symbol APIs:
370
371 5.1: get_tz_trend:
372 This function returns the trend of a thermal zone, i.e the rate of change
373 of temperature of the thermal zone. Ideally, the thermal sensor drivers
374 are supposed to implement the callback. If they don't, the thermal
375 framework calculated the trend by comparing the previous and the current
376 temperature values.
377
378 5.2:get_thermal_instance:
379 This function returns the thermal_instance corresponding to a given
380 {thermal_zone, cooling_device, trip_point} combination. Returns NULL
381 if such an instance does not exist.
382
383 5.3:thermal_notify_framework:
384 This function handles the trip events from sensor drivers. It starts
385 throttling the cooling devices according to the policy configured.
386 For CRITICAL and HOT trip points, this notifies the respective drivers,
387 and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
388 The throttling policy is based on the configured platform data; if no
389 platform data is provided, this uses the step_wise throttling policy.
390
391 5.4:thermal_cdev_update:
392 This function serves as an arbitrator to set the state of a cooling
393 device. It sets the cooling device to the deepest cooling state if
394 possible.