Merge branch 'for-upstream' of git://git.kernel.org/pub/scm/linux/kernel/git/bluetoot...
[GitHub/mt8127/android_kernel_alcatel_ttab.git] / drivers / power / ab8500_btemp.c
CommitLineData
1f855824
AM
1/*
2 * Copyright (C) ST-Ericsson SA 2012
3 *
4 * Battery temperature driver for AB8500
5 *
6 * License Terms: GNU General Public License v2
7 * Author:
8 * Johan Palsson <johan.palsson@stericsson.com>
9 * Karl Komierowski <karl.komierowski@stericsson.com>
10 * Arun R Murthy <arun.murthy@stericsson.com>
11 */
12
13#include <linux/init.h>
14#include <linux/module.h>
15#include <linux/device.h>
16#include <linux/interrupt.h>
17#include <linux/delay.h>
18#include <linux/slab.h>
19#include <linux/platform_device.h>
20#include <linux/power_supply.h>
21#include <linux/completion.h>
22#include <linux/workqueue.h>
bd9e8ab2
R
23#include <linux/jiffies.h>
24#include <linux/of.h>
25#include <linux/mfd/core.h>
1f855824 26#include <linux/mfd/abx500.h>
bd9e8ab2 27#include <linux/mfd/abx500/ab8500.h>
1f855824
AM
28#include <linux/mfd/abx500/ab8500-bm.h>
29#include <linux/mfd/abx500/ab8500-gpadc.h>
1f855824
AM
30
31#define VTVOUT_V 1800
32
33#define BTEMP_THERMAL_LOW_LIMIT -10
34#define BTEMP_THERMAL_MED_LIMIT 0
35#define BTEMP_THERMAL_HIGH_LIMIT_52 52
36#define BTEMP_THERMAL_HIGH_LIMIT_57 57
37#define BTEMP_THERMAL_HIGH_LIMIT_62 62
38
39#define BTEMP_BATCTRL_CURR_SRC_7UA 7
40#define BTEMP_BATCTRL_CURR_SRC_20UA 20
41
e6aac611
MJ
42#define BTEMP_BATCTRL_CURR_SRC_16UA 16
43#define BTEMP_BATCTRL_CURR_SRC_18UA 18
44
1f855824
AM
45#define to_ab8500_btemp_device_info(x) container_of((x), \
46 struct ab8500_btemp, btemp_psy);
47
48/**
49 * struct ab8500_btemp_interrupts - ab8500 interrupts
50 * @name: name of the interrupt
51 * @isr function pointer to the isr
52 */
53struct ab8500_btemp_interrupts {
54 char *name;
55 irqreturn_t (*isr)(int irq, void *data);
56};
57
58struct ab8500_btemp_events {
59 bool batt_rem;
60 bool btemp_high;
61 bool btemp_medhigh;
62 bool btemp_lowmed;
63 bool btemp_low;
64 bool ac_conn;
65 bool usb_conn;
66};
67
68struct ab8500_btemp_ranges {
69 int btemp_high_limit;
70 int btemp_med_limit;
71 int btemp_low_limit;
72};
73
74/**
75 * struct ab8500_btemp - ab8500 BTEMP device information
76 * @dev: Pointer to the structure device
77 * @node: List of AB8500 BTEMPs, hence prepared for reentrance
78 * @curr_source: What current source we use, in uA
79 * @bat_temp: Battery temperature in degree Celcius
80 * @prev_bat_temp Last dispatched battery temperature
81 * @parent: Pointer to the struct ab8500
82 * @gpadc: Pointer to the struct gpadc
83 * @fg: Pointer to the struct fg
b0284de0 84 * @bm: Platform specific battery management information
1f855824
AM
85 * @btemp_psy: Structure for BTEMP specific battery properties
86 * @events: Structure for information about events triggered
87 * @btemp_ranges: Battery temperature range structure
88 * @btemp_wq: Work queue for measuring the temperature periodically
89 * @btemp_periodic_work: Work for measuring the temperature periodically
f6271b4f 90 * @initialized: True if battery id read.
1f855824
AM
91 */
92struct ab8500_btemp {
93 struct device *dev;
94 struct list_head node;
95 int curr_source;
96 int bat_temp;
97 int prev_bat_temp;
98 struct ab8500 *parent;
99 struct ab8500_gpadc *gpadc;
100 struct ab8500_fg *fg;
b0284de0 101 struct abx500_bm_data *bm;
1f855824
AM
102 struct power_supply btemp_psy;
103 struct ab8500_btemp_events events;
104 struct ab8500_btemp_ranges btemp_ranges;
105 struct workqueue_struct *btemp_wq;
106 struct delayed_work btemp_periodic_work;
f6271b4f 107 bool initialized;
1f855824
AM
108};
109
110/* BTEMP power supply properties */
111static enum power_supply_property ab8500_btemp_props[] = {
112 POWER_SUPPLY_PROP_PRESENT,
113 POWER_SUPPLY_PROP_ONLINE,
114 POWER_SUPPLY_PROP_TECHNOLOGY,
115 POWER_SUPPLY_PROP_TEMP,
116};
117
118static LIST_HEAD(ab8500_btemp_list);
119
120/**
121 * ab8500_btemp_get() - returns a reference to the primary AB8500 BTEMP
122 * (i.e. the first BTEMP in the instance list)
123 */
124struct ab8500_btemp *ab8500_btemp_get(void)
125{
126 struct ab8500_btemp *btemp;
127 btemp = list_first_entry(&ab8500_btemp_list, struct ab8500_btemp, node);
128
129 return btemp;
130}
131
132/**
133 * ab8500_btemp_batctrl_volt_to_res() - convert batctrl voltage to resistance
134 * @di: pointer to the ab8500_btemp structure
135 * @v_batctrl: measured batctrl voltage
136 * @inst_curr: measured instant current
137 *
138 * This function returns the battery resistance that is
139 * derived from the BATCTRL voltage.
140 * Returns value in Ohms.
141 */
142static int ab8500_btemp_batctrl_volt_to_res(struct ab8500_btemp *di,
143 int v_batctrl, int inst_curr)
144{
145 int rbs;
146
147 if (is_ab8500_1p1_or_earlier(di->parent)) {
148 /*
149 * For ABB cut1.0 and 1.1 BAT_CTRL is internally
150 * connected to 1.8V through a 450k resistor
151 */
152 return (450000 * (v_batctrl)) / (1800 - v_batctrl);
153 }
154
b0284de0 155 if (di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL) {
1f855824
AM
156 /*
157 * If the battery has internal NTC, we use the current
158 * source to calculate the resistance, 7uA or 20uA
159 */
160 rbs = (v_batctrl * 1000
b0284de0 161 - di->bm->gnd_lift_resistance * inst_curr)
1f855824
AM
162 / di->curr_source;
163 } else {
164 /*
165 * BAT_CTRL is internally
166 * connected to 1.8V through a 80k resistor
167 */
168 rbs = (80000 * (v_batctrl)) / (1800 - v_batctrl);
169 }
170
171 return rbs;
172}
173
174/**
175 * ab8500_btemp_read_batctrl_voltage() - measure batctrl voltage
176 * @di: pointer to the ab8500_btemp structure
177 *
178 * This function returns the voltage on BATCTRL. Returns value in mV.
179 */
180static int ab8500_btemp_read_batctrl_voltage(struct ab8500_btemp *di)
181{
182 int vbtemp;
183 static int prev;
184
185 vbtemp = ab8500_gpadc_convert(di->gpadc, BAT_CTRL);
186 if (vbtemp < 0) {
187 dev_err(di->dev,
188 "%s gpadc conversion failed, using previous value",
189 __func__);
190 return prev;
191 }
192 prev = vbtemp;
193 return vbtemp;
194}
195
196/**
197 * ab8500_btemp_curr_source_enable() - enable/disable batctrl current source
198 * @di: pointer to the ab8500_btemp structure
199 * @enable: enable or disable the current source
200 *
201 * Enable or disable the current sources for the BatCtrl AD channel
202 */
203static int ab8500_btemp_curr_source_enable(struct ab8500_btemp *di,
204 bool enable)
205{
206 int curr;
207 int ret = 0;
208
209 /*
210 * BATCTRL current sources are included on AB8500 cut2.0
211 * and future versions
212 */
213 if (is_ab8500_1p1_or_earlier(di->parent))
214 return 0;
215
216 /* Only do this for batteries with internal NTC */
b0284de0 217 if (di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL && enable) {
e6aac611
MJ
218
219 if (is_ab9540(di->parent) || is_ab8505(di->parent)) {
220 if (di->curr_source == BTEMP_BATCTRL_CURR_SRC_16UA)
221 curr = BAT_CTRL_16U_ENA;
222 else
223 curr = BAT_CTRL_18U_ENA;
224 } else {
225 if (di->curr_source == BTEMP_BATCTRL_CURR_SRC_7UA)
226 curr = BAT_CTRL_7U_ENA;
227 else
228 curr = BAT_CTRL_20U_ENA;
229 }
1f855824
AM
230
231 dev_dbg(di->dev, "Set BATCTRL %duA\n", di->curr_source);
232
233 ret = abx500_mask_and_set_register_interruptible(di->dev,
234 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
235 FORCE_BAT_CTRL_CMP_HIGH, FORCE_BAT_CTRL_CMP_HIGH);
236 if (ret) {
237 dev_err(di->dev, "%s failed setting cmp_force\n",
238 __func__);
239 return ret;
240 }
241
242 /*
243 * We have to wait one 32kHz cycle before enabling
244 * the current source, since ForceBatCtrlCmpHigh needs
245 * to be written in a separate cycle
246 */
247 udelay(32);
248
249 ret = abx500_set_register_interruptible(di->dev,
250 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
251 FORCE_BAT_CTRL_CMP_HIGH | curr);
252 if (ret) {
253 dev_err(di->dev, "%s failed enabling current source\n",
254 __func__);
255 goto disable_curr_source;
256 }
b0284de0 257 } else if (di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL && !enable) {
1f855824
AM
258 dev_dbg(di->dev, "Disable BATCTRL curr source\n");
259
e6aac611
MJ
260 if (is_ab9540(di->parent) || is_ab8505(di->parent)) {
261 /* Write 0 to the curr bits */
262 ret = abx500_mask_and_set_register_interruptible(
263 di->dev,
264 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
265 BAT_CTRL_16U_ENA | BAT_CTRL_18U_ENA,
266 ~(BAT_CTRL_16U_ENA | BAT_CTRL_18U_ENA));
267 } else {
268 /* Write 0 to the curr bits */
269 ret = abx500_mask_and_set_register_interruptible(
270 di->dev,
271 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
272 BAT_CTRL_7U_ENA | BAT_CTRL_20U_ENA,
273 ~(BAT_CTRL_7U_ENA | BAT_CTRL_20U_ENA));
274 }
275
1f855824
AM
276 if (ret) {
277 dev_err(di->dev, "%s failed disabling current source\n",
278 __func__);
279 goto disable_curr_source;
280 }
281
282 /* Enable Pull-Up and comparator */
283 ret = abx500_mask_and_set_register_interruptible(di->dev,
284 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
285 BAT_CTRL_PULL_UP_ENA | BAT_CTRL_CMP_ENA,
286 BAT_CTRL_PULL_UP_ENA | BAT_CTRL_CMP_ENA);
287 if (ret) {
288 dev_err(di->dev, "%s failed enabling PU and comp\n",
289 __func__);
290 goto enable_pu_comp;
291 }
292
293 /*
294 * We have to wait one 32kHz cycle before disabling
295 * ForceBatCtrlCmpHigh since this needs to be written
296 * in a separate cycle
297 */
298 udelay(32);
299
300 /* Disable 'force comparator' */
301 ret = abx500_mask_and_set_register_interruptible(di->dev,
302 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
303 FORCE_BAT_CTRL_CMP_HIGH, ~FORCE_BAT_CTRL_CMP_HIGH);
304 if (ret) {
305 dev_err(di->dev, "%s failed disabling force comp\n",
306 __func__);
307 goto disable_force_comp;
308 }
309 }
310 return ret;
311
312 /*
313 * We have to try unsetting FORCE_BAT_CTRL_CMP_HIGH one more time
314 * if we got an error above
315 */
316disable_curr_source:
e6aac611
MJ
317 if (is_ab9540(di->parent) || is_ab8505(di->parent)) {
318 /* Write 0 to the curr bits */
319 ret = abx500_mask_and_set_register_interruptible(di->dev,
320 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
321 BAT_CTRL_16U_ENA | BAT_CTRL_18U_ENA,
322 ~(BAT_CTRL_16U_ENA | BAT_CTRL_18U_ENA));
323 } else {
324 /* Write 0 to the curr bits */
325 ret = abx500_mask_and_set_register_interruptible(di->dev,
1f855824
AM
326 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
327 BAT_CTRL_7U_ENA | BAT_CTRL_20U_ENA,
328 ~(BAT_CTRL_7U_ENA | BAT_CTRL_20U_ENA));
e6aac611
MJ
329 }
330
1f855824
AM
331 if (ret) {
332 dev_err(di->dev, "%s failed disabling current source\n",
333 __func__);
334 return ret;
335 }
336enable_pu_comp:
337 /* Enable Pull-Up and comparator */
338 ret = abx500_mask_and_set_register_interruptible(di->dev,
339 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
340 BAT_CTRL_PULL_UP_ENA | BAT_CTRL_CMP_ENA,
341 BAT_CTRL_PULL_UP_ENA | BAT_CTRL_CMP_ENA);
342 if (ret) {
343 dev_err(di->dev, "%s failed enabling PU and comp\n",
344 __func__);
345 return ret;
346 }
347
348disable_force_comp:
349 /*
350 * We have to wait one 32kHz cycle before disabling
351 * ForceBatCtrlCmpHigh since this needs to be written
352 * in a separate cycle
353 */
354 udelay(32);
355
356 /* Disable 'force comparator' */
357 ret = abx500_mask_and_set_register_interruptible(di->dev,
358 AB8500_CHARGER, AB8500_BAT_CTRL_CURRENT_SOURCE,
359 FORCE_BAT_CTRL_CMP_HIGH, ~FORCE_BAT_CTRL_CMP_HIGH);
360 if (ret) {
361 dev_err(di->dev, "%s failed disabling force comp\n",
362 __func__);
363 return ret;
364 }
365
366 return ret;
367}
368
369/**
370 * ab8500_btemp_get_batctrl_res() - get battery resistance
371 * @di: pointer to the ab8500_btemp structure
372 *
373 * This function returns the battery pack identification resistance.
374 * Returns value in Ohms.
375 */
376static int ab8500_btemp_get_batctrl_res(struct ab8500_btemp *di)
377{
378 int ret;
379 int batctrl = 0;
380 int res;
381 int inst_curr;
382 int i;
383
384 /*
385 * BATCTRL current sources are included on AB8500 cut2.0
386 * and future versions
387 */
388 ret = ab8500_btemp_curr_source_enable(di, true);
389 if (ret) {
390 dev_err(di->dev, "%s curr source enabled failed\n", __func__);
391 return ret;
392 }
393
394 if (!di->fg)
395 di->fg = ab8500_fg_get();
396 if (!di->fg) {
397 dev_err(di->dev, "No fg found\n");
398 return -EINVAL;
399 }
400
401 ret = ab8500_fg_inst_curr_start(di->fg);
402
403 if (ret) {
404 dev_err(di->dev, "Failed to start current measurement\n");
405 return ret;
406 }
407
3988a4df
JB
408 do {
409 msleep(20);
410 } while (!ab8500_fg_inst_curr_started(di->fg));
411
1f855824
AM
412 i = 0;
413
414 do {
415 batctrl += ab8500_btemp_read_batctrl_voltage(di);
416 i++;
417 msleep(20);
418 } while (!ab8500_fg_inst_curr_done(di->fg));
419 batctrl /= i;
420
421 ret = ab8500_fg_inst_curr_finalize(di->fg, &inst_curr);
422 if (ret) {
423 dev_err(di->dev, "Failed to finalize current measurement\n");
424 return ret;
425 }
426
427 res = ab8500_btemp_batctrl_volt_to_res(di, batctrl, inst_curr);
428
429 ret = ab8500_btemp_curr_source_enable(di, false);
430 if (ret) {
431 dev_err(di->dev, "%s curr source disable failed\n", __func__);
432 return ret;
433 }
434
435 dev_dbg(di->dev, "%s batctrl: %d res: %d inst_curr: %d samples: %d\n",
436 __func__, batctrl, res, inst_curr, i);
437
438 return res;
439}
440
441/**
442 * ab8500_btemp_res_to_temp() - resistance to temperature
443 * @di: pointer to the ab8500_btemp structure
444 * @tbl: pointer to the resiatance to temperature table
445 * @tbl_size: size of the resistance to temperature table
446 * @res: resistance to calculate the temperature from
447 *
448 * This function returns the battery temperature in degrees Celcius
449 * based on the NTC resistance.
450 */
451static int ab8500_btemp_res_to_temp(struct ab8500_btemp *di,
452 const struct abx500_res_to_temp *tbl, int tbl_size, int res)
453{
454 int i, temp;
455 /*
456 * Calculate the formula for the straight line
457 * Simple interpolation if we are within
458 * the resistance table limits, extrapolate
459 * if resistance is outside the limits.
460 */
461 if (res > tbl[0].resist)
462 i = 0;
463 else if (res <= tbl[tbl_size - 1].resist)
464 i = tbl_size - 2;
465 else {
466 i = 0;
467 while (!(res <= tbl[i].resist &&
468 res > tbl[i + 1].resist))
469 i++;
470 }
471
472 temp = tbl[i].temp + ((tbl[i + 1].temp - tbl[i].temp) *
473 (res - tbl[i].resist)) / (tbl[i + 1].resist - tbl[i].resist);
474 return temp;
475}
476
477/**
478 * ab8500_btemp_measure_temp() - measure battery temperature
479 * @di: pointer to the ab8500_btemp structure
480 *
481 * Returns battery temperature (on success) else the previous temperature
482 */
483static int ab8500_btemp_measure_temp(struct ab8500_btemp *di)
484{
485 int temp;
486 static int prev;
487 int rbat, rntc, vntc;
488 u8 id;
489
b0284de0 490 id = di->bm->batt_id;
1f855824 491
b0284de0 492 if (di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL &&
1f855824
AM
493 id != BATTERY_UNKNOWN) {
494
495 rbat = ab8500_btemp_get_batctrl_res(di);
496 if (rbat < 0) {
497 dev_err(di->dev, "%s get batctrl res failed\n",
498 __func__);
499 /*
500 * Return out-of-range temperature so that
501 * charging is stopped
502 */
503 return BTEMP_THERMAL_LOW_LIMIT;
504 }
505
506 temp = ab8500_btemp_res_to_temp(di,
b0284de0
LJ
507 di->bm->bat_type[id].r_to_t_tbl,
508 di->bm->bat_type[id].n_temp_tbl_elements, rbat);
1f855824
AM
509 } else {
510 vntc = ab8500_gpadc_convert(di->gpadc, BTEMP_BALL);
511 if (vntc < 0) {
512 dev_err(di->dev,
513 "%s gpadc conversion failed,"
514 " using previous value\n", __func__);
515 return prev;
516 }
517 /*
518 * The PCB NTC is sourced from VTVOUT via a 230kOhm
519 * resistor.
520 */
521 rntc = 230000 * vntc / (VTVOUT_V - vntc);
522
523 temp = ab8500_btemp_res_to_temp(di,
b0284de0
LJ
524 di->bm->bat_type[id].r_to_t_tbl,
525 di->bm->bat_type[id].n_temp_tbl_elements, rntc);
1f855824
AM
526 prev = temp;
527 }
528 dev_dbg(di->dev, "Battery temperature is %d\n", temp);
529 return temp;
530}
531
532/**
533 * ab8500_btemp_id() - Identify the connected battery
534 * @di: pointer to the ab8500_btemp structure
535 *
536 * This function will try to identify the battery by reading the ID
537 * resistor. Some brands use a combined ID resistor with a NTC resistor to
538 * both be able to identify and to read the temperature of it.
539 */
540static int ab8500_btemp_id(struct ab8500_btemp *di)
541{
542 int res;
543 u8 i;
e6aac611
MJ
544 if (is_ab9540(di->parent) || is_ab8505(di->parent))
545 di->curr_source = BTEMP_BATCTRL_CURR_SRC_16UA;
546 else
547 di->curr_source = BTEMP_BATCTRL_CURR_SRC_7UA;
1f855824 548
b0284de0 549 di->bm->batt_id = BATTERY_UNKNOWN;
1f855824
AM
550
551 res = ab8500_btemp_get_batctrl_res(di);
552 if (res < 0) {
553 dev_err(di->dev, "%s get batctrl res failed\n", __func__);
554 return -ENXIO;
555 }
556
557 /* BATTERY_UNKNOWN is defined on position 0, skip it! */
b0284de0
LJ
558 for (i = BATTERY_UNKNOWN + 1; i < di->bm->n_btypes; i++) {
559 if ((res <= di->bm->bat_type[i].resis_high) &&
560 (res >= di->bm->bat_type[i].resis_low)) {
1f855824
AM
561 dev_dbg(di->dev, "Battery detected on %s"
562 " low %d < res %d < high: %d"
563 " index: %d\n",
b0284de0 564 di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL ?
1f855824 565 "BATCTRL" : "BATTEMP",
b0284de0
LJ
566 di->bm->bat_type[i].resis_low, res,
567 di->bm->bat_type[i].resis_high, i);
1f855824 568
b0284de0 569 di->bm->batt_id = i;
1f855824
AM
570 break;
571 }
572 }
573
b0284de0 574 if (di->bm->batt_id == BATTERY_UNKNOWN) {
1f855824
AM
575 dev_warn(di->dev, "Battery identified as unknown"
576 ", resistance %d Ohm\n", res);
577 return -ENXIO;
578 }
579
580 /*
581 * We only have to change current source if the
582 * detected type is Type 1, else we use the 7uA source
583 */
b0284de0
LJ
584 if (di->bm->adc_therm == ABx500_ADC_THERM_BATCTRL &&
585 di->bm->batt_id == 1) {
e6aac611
MJ
586 if (is_ab9540(di->parent) || is_ab8505(di->parent)) {
587 dev_dbg(di->dev, "Set BATCTRL current source to 16uA\n");
588 di->curr_source = BTEMP_BATCTRL_CURR_SRC_16UA;
589 } else {
590 dev_dbg(di->dev, "Set BATCTRL current source to 20uA\n");
591 di->curr_source = BTEMP_BATCTRL_CURR_SRC_20UA;
592 }
1f855824
AM
593 }
594
b0284de0 595 return di->bm->batt_id;
1f855824
AM
596}
597
598/**
599 * ab8500_btemp_periodic_work() - Measuring the temperature periodically
600 * @work: pointer to the work_struct structure
601 *
602 * Work function for measuring the temperature periodically
603 */
604static void ab8500_btemp_periodic_work(struct work_struct *work)
605{
606 int interval;
607 struct ab8500_btemp *di = container_of(work,
608 struct ab8500_btemp, btemp_periodic_work.work);
609
f6271b4f
JA
610 if (!di->initialized) {
611 di->initialized = true;
612 /* Identify the battery */
613 if (ab8500_btemp_id(di) < 0)
614 dev_warn(di->dev, "failed to identify the battery\n");
615 }
616
1f855824
AM
617 di->bat_temp = ab8500_btemp_measure_temp(di);
618
619 if (di->bat_temp != di->prev_bat_temp) {
620 di->prev_bat_temp = di->bat_temp;
621 power_supply_changed(&di->btemp_psy);
622 }
623
624 if (di->events.ac_conn || di->events.usb_conn)
b0284de0 625 interval = di->bm->temp_interval_chg;
1f855824 626 else
b0284de0 627 interval = di->bm->temp_interval_nochg;
1f855824
AM
628
629 /* Schedule a new measurement */
630 queue_delayed_work(di->btemp_wq,
631 &di->btemp_periodic_work,
632 round_jiffies(interval * HZ));
633}
634
635/**
636 * ab8500_btemp_batctrlindb_handler() - battery removal detected
637 * @irq: interrupt number
638 * @_di: void pointer that has to address of ab8500_btemp
639 *
640 * Returns IRQ status(IRQ_HANDLED)
641 */
642static irqreturn_t ab8500_btemp_batctrlindb_handler(int irq, void *_di)
643{
644 struct ab8500_btemp *di = _di;
645 dev_err(di->dev, "Battery removal detected!\n");
646
647 di->events.batt_rem = true;
648 power_supply_changed(&di->btemp_psy);
649
650 return IRQ_HANDLED;
651}
652
653/**
654 * ab8500_btemp_templow_handler() - battery temp lower than 10 degrees
655 * @irq: interrupt number
656 * @_di: void pointer that has to address of ab8500_btemp
657 *
658 * Returns IRQ status(IRQ_HANDLED)
659 */
660static irqreturn_t ab8500_btemp_templow_handler(int irq, void *_di)
661{
662 struct ab8500_btemp *di = _di;
663
d36e3e6d 664 if (is_ab8500_3p3_or_earlier(di->parent)) {
1f855824 665 dev_dbg(di->dev, "Ignore false btemp low irq"
d36e3e6d 666 " for ABB cut 1.0, 1.1, 2.0 and 3.3\n");
1f855824
AM
667 } else {
668 dev_crit(di->dev, "Battery temperature lower than -10deg c\n");
669
670 di->events.btemp_low = true;
671 di->events.btemp_high = false;
672 di->events.btemp_medhigh = false;
673 di->events.btemp_lowmed = false;
674 power_supply_changed(&di->btemp_psy);
675 }
676
677 return IRQ_HANDLED;
678}
679
680/**
681 * ab8500_btemp_temphigh_handler() - battery temp higher than max temp
682 * @irq: interrupt number
683 * @_di: void pointer that has to address of ab8500_btemp
684 *
685 * Returns IRQ status(IRQ_HANDLED)
686 */
687static irqreturn_t ab8500_btemp_temphigh_handler(int irq, void *_di)
688{
689 struct ab8500_btemp *di = _di;
690
691 dev_crit(di->dev, "Battery temperature is higher than MAX temp\n");
692
693 di->events.btemp_high = true;
694 di->events.btemp_medhigh = false;
695 di->events.btemp_lowmed = false;
696 di->events.btemp_low = false;
697 power_supply_changed(&di->btemp_psy);
698
699 return IRQ_HANDLED;
700}
701
702/**
703 * ab8500_btemp_lowmed_handler() - battery temp between low and medium
704 * @irq: interrupt number
705 * @_di: void pointer that has to address of ab8500_btemp
706 *
707 * Returns IRQ status(IRQ_HANDLED)
708 */
709static irqreturn_t ab8500_btemp_lowmed_handler(int irq, void *_di)
710{
711 struct ab8500_btemp *di = _di;
712
713 dev_dbg(di->dev, "Battery temperature is between low and medium\n");
714
715 di->events.btemp_lowmed = true;
716 di->events.btemp_medhigh = false;
717 di->events.btemp_high = false;
718 di->events.btemp_low = false;
719 power_supply_changed(&di->btemp_psy);
720
721 return IRQ_HANDLED;
722}
723
724/**
725 * ab8500_btemp_medhigh_handler() - battery temp between medium and high
726 * @irq: interrupt number
727 * @_di: void pointer that has to address of ab8500_btemp
728 *
729 * Returns IRQ status(IRQ_HANDLED)
730 */
731static irqreturn_t ab8500_btemp_medhigh_handler(int irq, void *_di)
732{
733 struct ab8500_btemp *di = _di;
734
735 dev_dbg(di->dev, "Battery temperature is between medium and high\n");
736
737 di->events.btemp_medhigh = true;
738 di->events.btemp_lowmed = false;
739 di->events.btemp_high = false;
740 di->events.btemp_low = false;
741 power_supply_changed(&di->btemp_psy);
742
743 return IRQ_HANDLED;
744}
745
746/**
747 * ab8500_btemp_periodic() - Periodic temperature measurements
748 * @di: pointer to the ab8500_btemp structure
749 * @enable: enable or disable periodic temperature measurements
750 *
751 * Starts of stops periodic temperature measurements. Periodic measurements
752 * should only be done when a charger is connected.
753 */
754static void ab8500_btemp_periodic(struct ab8500_btemp *di,
755 bool enable)
756{
757 dev_dbg(di->dev, "Enable periodic temperature measurements: %d\n",
758 enable);
759 /*
760 * Make sure a new measurement is done directly by cancelling
761 * any pending work
762 */
763 cancel_delayed_work_sync(&di->btemp_periodic_work);
764
765 if (enable)
766 queue_delayed_work(di->btemp_wq, &di->btemp_periodic_work, 0);
767}
768
769/**
770 * ab8500_btemp_get_temp() - get battery temperature
771 * @di: pointer to the ab8500_btemp structure
772 *
773 * Returns battery temperature
774 */
775static int ab8500_btemp_get_temp(struct ab8500_btemp *di)
776{
777 int temp = 0;
778
779 /*
d36e3e6d 780 * The BTEMP events are not reliabe on AB8500 cut3.3
1f855824
AM
781 * and prior versions
782 */
d36e3e6d 783 if (is_ab8500_3p3_or_earlier(di->parent)) {
1f855824
AM
784 temp = di->bat_temp * 10;
785 } else {
786 if (di->events.btemp_low) {
787 if (temp > di->btemp_ranges.btemp_low_limit)
5b41aa9f 788 temp = di->btemp_ranges.btemp_low_limit * 10;
1f855824
AM
789 else
790 temp = di->bat_temp * 10;
791 } else if (di->events.btemp_high) {
792 if (temp < di->btemp_ranges.btemp_high_limit)
5b41aa9f 793 temp = di->btemp_ranges.btemp_high_limit * 10;
1f855824
AM
794 else
795 temp = di->bat_temp * 10;
796 } else if (di->events.btemp_lowmed) {
797 if (temp > di->btemp_ranges.btemp_med_limit)
5b41aa9f 798 temp = di->btemp_ranges.btemp_med_limit * 10;
1f855824
AM
799 else
800 temp = di->bat_temp * 10;
801 } else if (di->events.btemp_medhigh) {
802 if (temp < di->btemp_ranges.btemp_med_limit)
5b41aa9f 803 temp = di->btemp_ranges.btemp_med_limit * 10;
1f855824
AM
804 else
805 temp = di->bat_temp * 10;
806 } else
807 temp = di->bat_temp * 10;
808 }
809 return temp;
810}
811
812/**
813 * ab8500_btemp_get_batctrl_temp() - get the temperature
814 * @btemp: pointer to the btemp structure
815 *
816 * Returns the batctrl temperature in millidegrees
817 */
818int ab8500_btemp_get_batctrl_temp(struct ab8500_btemp *btemp)
819{
820 return btemp->bat_temp * 1000;
821}
822
823/**
824 * ab8500_btemp_get_property() - get the btemp properties
825 * @psy: pointer to the power_supply structure
826 * @psp: pointer to the power_supply_property structure
827 * @val: pointer to the power_supply_propval union
828 *
829 * This function gets called when an application tries to get the btemp
830 * properties by reading the sysfs files.
831 * online: presence of the battery
832 * present: presence of the battery
833 * technology: battery technology
834 * temp: battery temperature
835 * Returns error code in case of failure else 0(on success)
836 */
837static int ab8500_btemp_get_property(struct power_supply *psy,
838 enum power_supply_property psp,
839 union power_supply_propval *val)
840{
841 struct ab8500_btemp *di;
842
843 di = to_ab8500_btemp_device_info(psy);
844
845 switch (psp) {
846 case POWER_SUPPLY_PROP_PRESENT:
847 case POWER_SUPPLY_PROP_ONLINE:
848 if (di->events.batt_rem)
849 val->intval = 0;
850 else
851 val->intval = 1;
852 break;
853 case POWER_SUPPLY_PROP_TECHNOLOGY:
b0284de0 854 val->intval = di->bm->bat_type[di->bm->batt_id].name;
1f855824
AM
855 break;
856 case POWER_SUPPLY_PROP_TEMP:
857 val->intval = ab8500_btemp_get_temp(di);
858 break;
859 default:
860 return -EINVAL;
861 }
862 return 0;
863}
864
865static int ab8500_btemp_get_ext_psy_data(struct device *dev, void *data)
866{
867 struct power_supply *psy;
868 struct power_supply *ext;
869 struct ab8500_btemp *di;
870 union power_supply_propval ret;
871 int i, j;
872 bool psy_found = false;
873
874 psy = (struct power_supply *)data;
875 ext = dev_get_drvdata(dev);
876 di = to_ab8500_btemp_device_info(psy);
877
878 /*
879 * For all psy where the name of your driver
880 * appears in any supplied_to
881 */
882 for (i = 0; i < ext->num_supplicants; i++) {
883 if (!strcmp(ext->supplied_to[i], psy->name))
884 psy_found = true;
885 }
886
887 if (!psy_found)
888 return 0;
889
890 /* Go through all properties for the psy */
891 for (j = 0; j < ext->num_properties; j++) {
892 enum power_supply_property prop;
893 prop = ext->properties[j];
894
895 if (ext->get_property(ext, prop, &ret))
896 continue;
897
898 switch (prop) {
899 case POWER_SUPPLY_PROP_PRESENT:
900 switch (ext->type) {
901 case POWER_SUPPLY_TYPE_MAINS:
902 /* AC disconnected */
903 if (!ret.intval && di->events.ac_conn) {
904 di->events.ac_conn = false;
905 }
906 /* AC connected */
907 else if (ret.intval && !di->events.ac_conn) {
908 di->events.ac_conn = true;
909 if (!di->events.usb_conn)
910 ab8500_btemp_periodic(di, true);
911 }
912 break;
913 case POWER_SUPPLY_TYPE_USB:
914 /* USB disconnected */
915 if (!ret.intval && di->events.usb_conn) {
916 di->events.usb_conn = false;
917 }
918 /* USB connected */
919 else if (ret.intval && !di->events.usb_conn) {
920 di->events.usb_conn = true;
921 if (!di->events.ac_conn)
922 ab8500_btemp_periodic(di, true);
923 }
924 break;
925 default:
926 break;
927 }
928 break;
929 default:
930 break;
931 }
932 }
933 return 0;
934}
935
936/**
937 * ab8500_btemp_external_power_changed() - callback for power supply changes
938 * @psy: pointer to the structure power_supply
939 *
940 * This function is pointing to the function pointer external_power_changed
941 * of the structure power_supply.
942 * This function gets executed when there is a change in the external power
943 * supply to the btemp.
944 */
945static void ab8500_btemp_external_power_changed(struct power_supply *psy)
946{
947 struct ab8500_btemp *di = to_ab8500_btemp_device_info(psy);
948
949 class_for_each_device(power_supply_class, NULL,
950 &di->btemp_psy, ab8500_btemp_get_ext_psy_data);
951}
952
953/* ab8500 btemp driver interrupts and their respective isr */
954static struct ab8500_btemp_interrupts ab8500_btemp_irq[] = {
955 {"BAT_CTRL_INDB", ab8500_btemp_batctrlindb_handler},
956 {"BTEMP_LOW", ab8500_btemp_templow_handler},
957 {"BTEMP_HIGH", ab8500_btemp_temphigh_handler},
958 {"BTEMP_LOW_MEDIUM", ab8500_btemp_lowmed_handler},
959 {"BTEMP_MEDIUM_HIGH", ab8500_btemp_medhigh_handler},
960};
961
962#if defined(CONFIG_PM)
963static int ab8500_btemp_resume(struct platform_device *pdev)
964{
965 struct ab8500_btemp *di = platform_get_drvdata(pdev);
966
967 ab8500_btemp_periodic(di, true);
968
969 return 0;
970}
971
972static int ab8500_btemp_suspend(struct platform_device *pdev,
973 pm_message_t state)
974{
975 struct ab8500_btemp *di = platform_get_drvdata(pdev);
976
977 ab8500_btemp_periodic(di, false);
978
979 return 0;
980}
981#else
982#define ab8500_btemp_suspend NULL
983#define ab8500_btemp_resume NULL
984#endif
985
415ec69f 986static int ab8500_btemp_remove(struct platform_device *pdev)
1f855824
AM
987{
988 struct ab8500_btemp *di = platform_get_drvdata(pdev);
989 int i, irq;
990
991 /* Disable interrupts */
992 for (i = 0; i < ARRAY_SIZE(ab8500_btemp_irq); i++) {
993 irq = platform_get_irq_byname(pdev, ab8500_btemp_irq[i].name);
994 free_irq(irq, di);
995 }
996
997 /* Delete the work queue */
998 destroy_workqueue(di->btemp_wq);
999
1000 flush_scheduled_work();
1001 power_supply_unregister(&di->btemp_psy);
1002 platform_set_drvdata(pdev, NULL);
1f855824
AM
1003
1004 return 0;
1005}
1006
bd9e8ab2
R
1007static char *supply_interface[] = {
1008 "ab8500_chargalg",
1009 "ab8500_fg",
1010};
1011
c8afa640 1012static int ab8500_btemp_probe(struct platform_device *pdev)
1f855824 1013{
bd9e8ab2 1014 struct device_node *np = pdev->dev.of_node;
95820245 1015 struct abx500_bm_data *plat = pdev->dev.platform_data;
e0f1abeb 1016 struct ab8500_btemp *di;
1f855824
AM
1017 int irq, i, ret = 0;
1018 u8 val;
2aac3de1 1019
bd9e8ab2
R
1020 di = devm_kzalloc(&pdev->dev, sizeof(*di), GFP_KERNEL);
1021 if (!di) {
1022 dev_err(&pdev->dev, "%s no mem for ab8500_btemp\n", __func__);
1f855824 1023 return -ENOMEM;
bd9e8ab2 1024 }
95820245
LJ
1025
1026 if (!plat) {
1027 dev_err(&pdev->dev, "no battery management data supplied\n");
1028 return -EINVAL;
1029 }
1030 di->bm = plat;
1031
1032 if (np) {
1033 ret = ab8500_bm_of_probe(&pdev->dev, np, di->bm);
1034 if (ret) {
1035 dev_err(&pdev->dev, "failed to get battery information\n");
1036 return ret;
bd9e8ab2 1037 }
bd9e8ab2 1038 }
1f855824
AM
1039
1040 /* get parent data */
1041 di->dev = &pdev->dev;
1042 di->parent = dev_get_drvdata(pdev->dev.parent);
1043 di->gpadc = ab8500_gpadc_get("ab8500-gpadc.0");
1044
f6271b4f
JA
1045 di->initialized = false;
1046
1f855824
AM
1047 /* BTEMP supply */
1048 di->btemp_psy.name = "ab8500_btemp";
1049 di->btemp_psy.type = POWER_SUPPLY_TYPE_BATTERY;
1050 di->btemp_psy.properties = ab8500_btemp_props;
1051 di->btemp_psy.num_properties = ARRAY_SIZE(ab8500_btemp_props);
1052 di->btemp_psy.get_property = ab8500_btemp_get_property;
bd9e8ab2
R
1053 di->btemp_psy.supplied_to = supply_interface;
1054 di->btemp_psy.num_supplicants = ARRAY_SIZE(supply_interface);
1f855824
AM
1055 di->btemp_psy.external_power_changed =
1056 ab8500_btemp_external_power_changed;
1057
1058
1059 /* Create a work queue for the btemp */
1060 di->btemp_wq =
1061 create_singlethread_workqueue("ab8500_btemp_wq");
1062 if (di->btemp_wq == NULL) {
1063 dev_err(di->dev, "failed to create work queue\n");
bd9e8ab2 1064 return -ENOMEM;
1f855824
AM
1065 }
1066
1067 /* Init work for measuring temperature periodically */
203b42f7 1068 INIT_DEFERRABLE_WORK(&di->btemp_periodic_work,
1f855824
AM
1069 ab8500_btemp_periodic_work);
1070
1f855824 1071 /* Set BTEMP thermal limits. Low and Med are fixed */
0cdaf9a9
HB
1072 di->btemp_ranges.btemp_low_limit = BTEMP_THERMAL_LOW_LIMIT;
1073 di->btemp_ranges.btemp_med_limit = BTEMP_THERMAL_MED_LIMIT;
1f855824
AM
1074
1075 ret = abx500_get_register_interruptible(di->dev, AB8500_CHARGER,
1076 AB8500_BTEMP_HIGH_TH, &val);
1077 if (ret < 0) {
1078 dev_err(di->dev, "%s ab8500 read failed\n", __func__);
1079 goto free_btemp_wq;
1080 }
1081 switch (val) {
1082 case BTEMP_HIGH_TH_57_0:
1083 case BTEMP_HIGH_TH_57_1:
1084 di->btemp_ranges.btemp_high_limit =
1085 BTEMP_THERMAL_HIGH_LIMIT_57;
1086 break;
1087 case BTEMP_HIGH_TH_52:
1088 di->btemp_ranges.btemp_high_limit =
1089 BTEMP_THERMAL_HIGH_LIMIT_52;
1090 break;
1091 case BTEMP_HIGH_TH_62:
1092 di->btemp_ranges.btemp_high_limit =
1093 BTEMP_THERMAL_HIGH_LIMIT_62;
1094 break;
1095 }
1096
1097 /* Register BTEMP power supply class */
1098 ret = power_supply_register(di->dev, &di->btemp_psy);
1099 if (ret) {
1100 dev_err(di->dev, "failed to register BTEMP psy\n");
1101 goto free_btemp_wq;
1102 }
1103
1104 /* Register interrupts */
1105 for (i = 0; i < ARRAY_SIZE(ab8500_btemp_irq); i++) {
1106 irq = platform_get_irq_byname(pdev, ab8500_btemp_irq[i].name);
1107 ret = request_threaded_irq(irq, NULL, ab8500_btemp_irq[i].isr,
1108 IRQF_SHARED | IRQF_NO_SUSPEND,
1109 ab8500_btemp_irq[i].name, di);
1110
1111 if (ret) {
1112 dev_err(di->dev, "failed to request %s IRQ %d: %d\n"
1113 , ab8500_btemp_irq[i].name, irq, ret);
1114 goto free_irq;
1115 }
1116 dev_dbg(di->dev, "Requested %s IRQ %d: %d\n",
1117 ab8500_btemp_irq[i].name, irq, ret);
1118 }
1119
1120 platform_set_drvdata(pdev, di);
1121
1122 /* Kick off periodic temperature measurements */
1123 ab8500_btemp_periodic(di, true);
1124 list_add_tail(&di->node, &ab8500_btemp_list);
1125
1126 return ret;
1127
1128free_irq:
1129 power_supply_unregister(&di->btemp_psy);
1130
1131 /* We also have to free all successfully registered irqs */
1132 for (i = i - 1; i >= 0; i--) {
1133 irq = platform_get_irq_byname(pdev, ab8500_btemp_irq[i].name);
1134 free_irq(irq, di);
1135 }
1136free_btemp_wq:
1137 destroy_workqueue(di->btemp_wq);
1f855824
AM
1138 return ret;
1139}
1140
bd9e8ab2
R
1141static const struct of_device_id ab8500_btemp_match[] = {
1142 { .compatible = "stericsson,ab8500-btemp", },
1143 { },
1144};
1145
1f855824
AM
1146static struct platform_driver ab8500_btemp_driver = {
1147 .probe = ab8500_btemp_probe,
28ea73f4 1148 .remove = ab8500_btemp_remove,
1f855824
AM
1149 .suspend = ab8500_btemp_suspend,
1150 .resume = ab8500_btemp_resume,
1151 .driver = {
1152 .name = "ab8500-btemp",
1153 .owner = THIS_MODULE,
bd9e8ab2 1154 .of_match_table = ab8500_btemp_match,
1f855824
AM
1155 },
1156};
1157
1158static int __init ab8500_btemp_init(void)
1159{
1160 return platform_driver_register(&ab8500_btemp_driver);
1161}
1162
1163static void __exit ab8500_btemp_exit(void)
1164{
1165 platform_driver_unregister(&ab8500_btemp_driver);
1166}
1167
eeb0751c 1168device_initcall(ab8500_btemp_init);
1f855824
AM
1169module_exit(ab8500_btemp_exit);
1170
1171MODULE_LICENSE("GPL v2");
1172MODULE_AUTHOR("Johan Palsson, Karl Komierowski, Arun R Murthy");
1173MODULE_ALIAS("platform:ab8500-btemp");
1174MODULE_DESCRIPTION("AB8500 battery temperature driver");