203d3d4a 1Generic Thermal Sysfs driver How To
38bb0849 2===================================
203d3d4a
ZR
3
4Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6Updated: 2 January 2008
7
8Copyright (c) 2008 Intel Corporation
9
10
110. Introduction
12
38bb0849
FP
13The generic thermal sysfs provides a set of interfaces for thermal zone
14devices (sensors) and thermal cooling devices (fan, processor...) to register
15with the thermal management solution and to be a part of it.
203d3d4a 16
38bb0849
FP
17This how-to focuses on enabling new thermal zone and cooling devices to
18participate in thermal management.
19This solution is platform independent and any type of thermal zone devices
20and cooling devices should be able to make use of the infrastructure.
203d3d4a 21
38bb0849
FP
22The main task of the thermal sysfs driver is to expose thermal zone attributes
23as well as cooling device attributes to the user space.
24An intelligent thermal management application can make decisions based on
25inputs from thermal zone attributes (the current temperature and trip point
26temperature) and throttle appropriate devices.
203d3d4a
ZR
27
28[0-*] denotes any positive number starting from 0
29[1-*] denotes any positive number starting from 1
30
311. thermal sysfs driver interface functions
32
331.1 thermal zone device interface
38bb0849 341.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
c56f5c03
D
35 int trips, int mask, void *devdata,
36 struct thermal_zone_device_ops *ops)
38bb0849
FP
37
38 This interface function adds a new thermal zone device (sensor) to
39 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
40 thermal cooling devices registered at the same time.
41
42 name: the thermal zone name.
43 trips: the total number of trip points this thermal zone supports.
c56f5c03 44 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
38bb0849
FP
45 devdata: device private data
46 ops: thermal zone device call-backs.
47 .bind: bind the thermal zone device with a thermal cooling device.
48 .unbind: unbind the thermal zone device with a thermal cooling device.
49 .get_temp: get the current temperature of the thermal zone.
50 .get_mode: get the current mode (user/kernel) of the thermal zone.
51 - "kernel" means thermal management is done in kernel.
52 - "user" will prevent kernel thermal driver actions upon trip points
53 so that user applications can take charge of thermal management.
54 .set_mode: set the mode (user/kernel) of the thermal zone.
55 .get_trip_type: get the type of certain trip point.
56 .get_trip_temp: get the temperature above which the certain trip point
57 will be fired.
203d3d4a
ZR
58
591.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
60
38bb0849
FP
61 This interface function removes the thermal zone device.
62 It deletes the corresponding entry form /sys/class/thermal folder and
63 unbind all the thermal cooling devices it uses.
203d3d4a
ZR
64
651.2 thermal cooling device interface
661.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
38bb0849
FP
67 void *devdata, struct thermal_cooling_device_ops *)
68
69 This interface function adds a new thermal cooling device (fan/processor/...)
70 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
71 to all the thermal zone devices register at the same time.
72 name: the cooling device name.
73 devdata: device private data.
74 ops: thermal cooling devices call-backs.
75 .get_max_state: get the Maximum throttle state of the cooling device.
76 .get_cur_state: get the Current throttle state of the cooling device.
77 .set_cur_state: set the Current throttle state of the cooling device.
203d3d4a
ZR
78
791.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
80
38bb0849
FP
81 This interface function remove the thermal cooling device.
82 It deletes the corresponding entry form /sys/class/thermal folder and
83 unbind itself from all the thermal zone devices using it.
203d3d4a
ZR
84
851.3 interface for binding a thermal zone device with a thermal cooling device
861.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
38bb0849 87 int trip, struct thermal_cooling_device *cdev);
203d3d4a 88
38bb0849
FP
89 This interface function bind a thermal cooling device to the certain trip
90 point of a thermal zone device.
91 This function is usually called in the thermal zone device .bind callback.
92 tz: the thermal zone device
93 cdev: thermal cooling device
94 trip: indicates which trip point the cooling devices is associated with
95 in this thermal zone.
203d3d4a
ZR
96
971.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
38bb0849 98 int trip, struct thermal_cooling_device *cdev);
203d3d4a 99
38bb0849
FP
100 This interface function unbind a thermal cooling device from the certain
101 trip point of a thermal zone device. This function is usually called in
102 the thermal zone device .unbind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
203d3d4a
ZR
107
1082. sysfs attributes structure
109
110RO read only value
111RW read/write value
112
e9ae7107
ZR
113Thermal sysfs attributes will be represented under /sys/class/thermal.
114Hwmon sysfs I/F extension is also available under /sys/class/hwmon
115if hwmon is compiled in or built as a module.
203d3d4a
ZR
116
117Thermal zone device sys I/F, created once it's registered:
e9ae7107 118/sys/class/thermal/thermal_zone[0-*]:
38bb0849
FP
119 |---type: Type of the thermal zone
120 |---temp: Current temperature
121 |---mode: Working mode of the thermal zone
122 |---trip_point_[0-*]_temp: Trip point temperature
123 |---trip_point_[0-*]_type: Trip point type
27365a6c 124 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
203d3d4a
ZR
125
126Thermal cooling device sys I/F, created once it's registered:
e9ae7107 127/sys/class/thermal/cooling_device[0-*]:
38bb0849
FP
128 |---type: Type of the cooling device(processor/fan/...)
129 |---max_state: Maximum cooling state of the cooling device
130 |---cur_state: Current cooling state of the cooling device
203d3d4a
ZR
131
132
38bb0849
FP
133Then next two dynamic attributes are created/removed in pairs. They represent
134the relationship between a thermal zone and its associated cooling device.
135They are created/removed for each successful execution of
136thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
203d3d4a 137
38bb0849
FP
138/sys/class/thermal/thermal_zone[0-*]:
139 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
140 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
203d3d4a 141
e9ae7107 142Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
38bb0849
FP
143the generic thermal driver also creates a hwmon sysfs I/F for each _type_
144of thermal zone device. E.g. the generic thermal driver registers one hwmon
145class device and build the associated hwmon sysfs I/F for all the registered
146ACPI thermal zones.
147
e9ae7107 148/sys/class/hwmon/hwmon[0-*]:
38bb0849
FP
149 |---name: The type of the thermal zone devices
150 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
151 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
152
e9ae7107 153Please read Documentation/hwmon/sysfs-interface for additional information.
203d3d4a
ZR
154
155***************************
156* Thermal zone attributes *
157***************************
158
38bb0849
FP
159type
160 Strings which represent the thermal zone type.
161 This is given by thermal zone driver as part of registration.
162 E.g: "acpitz" indicates it's an ACPI thermal device.
163 In order to keep it consistent with hwmon sys attribute; this should
164 be a short, lowercase string, not containing spaces nor dashes.
165 RO, Required
166
167temp
168 Current temperature as reported by thermal zone (sensor).
169 Unit: millidegree Celsius
170 RO, Required
171
172mode
173 One of the predefined values in [kernel, user].
174 This file gives information about the algorithm that is currently
175 managing the thermal zone. It can be either default kernel based
176 algorithm or user space application.
177 kernel = Thermal management in kernel thermal zone driver.
178 user = Preventing kernel thermal zone driver actions upon
179 trip points so that user application can take full
180 charge of the thermal management.
181 RW, Optional
182
183trip_point_[0-*]_temp
184 The temperature above which trip point will be fired.
185 Unit: millidegree Celsius
186 RO, Optional
187
188trip_point_[0-*]_type
189 Strings which indicate the type of the trip point.
190 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
191 thermal zone.
192 RO, Optional
193
27365a6c
D
194trip_point_[0-*]_hyst
195 The hysteresis value for a trip point, represented as an integer
196 Unit: Celsius
197 RW, Optional
198
38bb0849
FP
199cdev[0-*]
200 Sysfs link to the thermal cooling device node where the sys I/F
201 for cooling device throttling control represents.
202 RO, Optional
203
204cdev[0-*]_trip_point
205 The trip point with which cdev[0-*] is associated in this thermal
206 zone; -1 means the cooling device is not associated with any trip
207 point.
208 RO, Optional
29226ed3
FP
209
210passive
211 Attribute is only present for zones in which the passive cooling
212 policy is not supported by native thermal driver. Default is zero
213 and can be set to a temperature (in millidegrees) to enable a
214 passive trip point for the zone. Activation is done by polling with
215 an interval of 1 second.
216 Unit: millidegrees Celsius
3d8e3ad8 217 Valid values: 0 (disabled) or greater than 1000
29226ed3 218 RW, Optional
38bb0849
FP
219
220*****************************
221* Cooling device attributes *
222*****************************
223
224type
225 String which represents the type of device, e.g:
226 - for generic ACPI: should be "Fan", "Processor" or "LCD"
227 - for memory controller device on intel_menlow platform:
228 should be "Memory controller".
229 RO, Required
230
231max_state
232 The maximum permissible cooling state of this cooling device.
233 RO, Required
234
235cur_state
236 The current cooling state of this cooling device.
237 The value can any integer numbers between 0 and max_state:
238 - cur_state == 0 means no cooling
239 - cur_state == max_state means the maximum cooling.
240 RW, Required
203d3d4a
ZR
241
2423. A simple implementation
243
38bb0849
FP
244ACPI thermal zone may support multiple trip points like critical, hot,
245passive, active. If an ACPI thermal zone supports critical, passive,
246active[0] and active[1] at the same time, it may register itself as a
247thermal_zone_device (thermal_zone1) with 4 trip points in all.
248It has one processor and one fan, which are both registered as
249thermal_cooling_device.
250
251If the processor is listed in _PSL method, and the fan is listed in _AL0
252method, the sys I/F structure will be built like this:
203d3d4a
ZR
253
254/sys/class/thermal:
255
256|thermal_zone1:
38bb0849
FP
257 |---type: acpitz
258 |---temp: 37000
259 |---mode: kernel
260 |---trip_point_0_temp: 100000
261 |---trip_point_0_type: critical
262 |---trip_point_1_temp: 80000
263 |---trip_point_1_type: passive
264 |---trip_point_2_temp: 70000
265 |---trip_point_2_type: active0
266 |---trip_point_3_temp: 60000
267 |---trip_point_3_type: active1
268 |---cdev0: --->/sys/class/thermal/cooling_device0
269 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
270 |---cdev1: --->/sys/class/thermal/cooling_device3
271 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
203d3d4a
ZR
272
273|cooling_device0:
38bb0849
FP
274 |---type: Processor
275 |---max_state: 8
276 |---cur_state: 0
203d3d4a
ZR
277
278|cooling_device3:
38bb0849
FP
279 |---type: Fan
280 |---max_state: 2
281 |---cur_state: 0
e9ae7107
ZR
282
283/sys/class/hwmon:
284
285|hwmon0:
38bb0849
FP
286 |---name: acpitz
287 |---temp1_input: 37000
288 |---temp1_crit: 100000
4cb18728
D
289
2904. Event Notification
291
292The framework includes a simple notification mechanism, in the form of a
293netlink event. Netlink socket initialization is done during the _init_
294of the framework. Drivers which intend to use the notification mechanism
2d58d7ea 295just need to call thermal_generate_netlink_event() with two arguments viz
4cb18728
D
296(originator, event). Typically the originator will be an integer assigned
297to a thermal_zone_device when it registers itself with the framework. The
298event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
299THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
300crosses any of the configured thresholds.